Faults & Effective Elimination Method of Adsorption Dryers
Adsorption dryer use the characteristics of absorbing moisture of adsorbent (activated alumina, silica gel, molecular sieve) to reduce water content of compressed air. in general, it can make pressure dew point of outlet end reach -40 ℃ above. however, equipment will cause some malfunctions for various reasons, resulting in it can not operate properly, or pressure dew point does not meet corresponding standard in many cases. what are failures for adsorption dryer? what is effective exclusion method?
First, adsorption dryer doesn’t work when press the switch
Reason
|
Solution
| |
1
|
No current input
|
Cheak power supply
|
2
|
Switch failure
|
Replace swith
|
3
|
Circuit breaker isn’t close
|
Close circuit breaker
|
4
|
Program controller failure or lose program
|
Contact manufacturer
|
5
|
Wiring fall off or virtual connection of program
|
Reconnect wire
|
Second, slightly higher dew point
Reason
|
Solution
| |
1
|
Compressed air capacity exceeds maximum
|
Replace larger capacity specifications
|
2
|
Adsorbent exceeds service life
|
Replace adsorbent
|
3
|
Adsorbent is contaminated
|
Replace adsorbent after cheaking front filter
|
4
|
Too low intake pressureor too high intake temperature
|
Increase intake pressure or reduce intake temperature
|
5
|
Too small regeneration gas amount
|
Increase regeneration gas amount
|
6
|
Too low regenerative gas temperature
|
Re-set heating temperature
|
Third, ram-type doesn’t reach work pressure
Reason
|
Solution
| |
1
|
Regeneration valve doesn’t close tightly
|
Check regeneration valve and
solenoid valve
|
2
|
Short stamping time
|
Modify time and contact
manufacturer
|
3
|
Regeneration one way valve can’t open
|
Replace one way valve
|
Fourth, the operation silencer has large exhaust when operation
Reason
|
Solution
| |
1
|
Changeover valve failure
|
Replace changeover valve
|
2
|
Intake solenoid valve failure
|
Replace solenoid valve
|
3
|
Output program of controller is incorrect or hardware problem
|
Replace spare parts or contact manufacturer
|
4
|
One way valve is stuck or malfunctioning by foreign matter
|
Maintain or replace
|
5
|
Too big regeneration gas
|
Turn down regeneration gas valve
|
Fifth, a large number of drainage for silencers when running
Reason
|
Solution
| |
1
|
Front filter is poorly drained
|
Clear drainer or replace
|
2
|
Regeneration gas is too small
|
Increase regeneration gas amount
|
3
|
Too low Regeneration gas temperature
|
Turn up generation temperature
|
Six, The device is large pressure drop when running
Reason
|
Solution
| |
1
|
Filter cartridge is blocked
|
Replace filter cartridge
|
2
|
Equipment has leak phenomenon
|
Eliminate leakage
|
Above six point possibly exist fault and corresponding elimination method for adsorption dryer when using. It may not absolute based on actual situation to choose an effective way to exclude. we should maintain equipment well for regularly maintaining equipment when using adsorption dryer, reducing or avoiding unnecessary equipment maintenance.